Satyasales a leading seller of Bard Fluency covered graft, Noida, Faridabad and NCR provides authentic Medtronic products North India. We deals Abott products since 2011 and also dealing in various cardiac surgical products used in implantation of various Cardiology / Cardiac Surgery The company was established in 2011.
SATYA SALES having good stock of Fluency™ Plus Endovascular Stent Graft .
A broad range of implant diameters and lengths for the treatment of in-stent restenotic peripheral and central lesions* in patients with AV grafts and AV fistulae .
Bard Fluency covered graft Small incremental stent graft lengths to help maintain venous real estate and cannulation area
Bard Fluency covered graft Minimal shortening and radiopaque markers aid in excellent placement accuracy
A broad range of implant diameters and lengths for the treatment of in-stent restenotic peripheral and central lesions* in patients with AV grafts and AV fistulae
Small incremental stent graft lengths to help maintain venous real estate and cannulation area
Minimal shortening and radiopaque markers aid in excellent placement accuracy
Fluency Plus Endovascular Stent Graft is an innovative medical device used in the treatment of aortic aneurysms, particularly abdominal aortic aneurysms (AAA).
Minimally Invasive Procedure : Fluency Plus Endovascular Stent Graft is deployed using a minimally invasive endovascular approach, which involves accessing the blood vessels through small incisions in the groin area. This approach eliminates the need for traditional open surgery, resulting in reduced trauma to the body, shorter hospital stays, and quicker recovery times for patients.
Aortic Aneurysm Repair : The primary purpose of Fluency Plus Endovascular Stent Graft is to reinforce the weakened or bulging wall of the aorta, thereby preventing the risk of rupture or dissection associated with aortic aneurysms. By deploying the stent graft within the diseased segment of the aorta, it provides a stable scaffold that allows blood to flow freely while excluding the aneurysmal sac from circulation, reducing the risk of complications.
Customized Treatment : Fluency Plus Endovascular Stent Graft is available in various sizes and configurations, allowing physicians to tailor the treatment to each patient's specific anatomical requirements. This customization ensures optimal fit and sealing, minimizing the risk of endoleaks (persistent blood flow within the aneurysm sac) and improving long-term outcomes.
Durability and Longevity : The stent graft is constructed from durable materials designed to withstand the hemodynamic forces within the aorta and maintain structural integrity over time. This durability ensures long-term stability and reduces the need for additional interventions or reoperations, leading to improved patient outcomes and quality of life.
Preservation of Aortic Function : Fluency Plus Endovascular Stent Graft preserves the natural physiological function of the aorta by maintaining blood flow to vital organs while excluding the diseased portion of the vessel. This minimizes the risk of complications such as thrombosis, embolization, or end-organ ischemia, ensuring optimal patient safety and vascular health.
Enhanced Patient Experience : Compared to traditional open surgery, endovascular repair with Fluency Plus Endovascular Stent Graft offers patients a less invasive treatment option with reduced postoperative pain, shorter recovery times, and lower rates of complications. This results in improved patient satisfaction and overall treatment experience.
In summary, Fluency Plus Endovascular Stent Graft offers numerous benefits in the treatment of aortic aneurysms, including minimally invasive deployment, customized treatment options, durability, preservation of aortic function, and enhanced patient experience. These advantages make it an effective and preferred choice for patients and healthcare providers seeking optimal outcomes in the management of aortic aneurysmal disease.
S.No. | Catheter Diameter | Catheter Length | Guidewire Length | Stent Graft Diameter | Stent Graft Length |
---|---|---|---|---|---|
1. | 10 F | 80 cm | 0.035 in | 13.5 mm | 120 mm |
2. | 9F | 80 cm | 0.035 in | 9 mm | 40 mm |
3. | 80 cm | 6 mm | 120mm | ||
4. | 9F | 80 cm | 0.035 in | 8 mm | 100 mm |
5. | 10F | 80 cm | 0.035 in | 12 mm | 120 mm |
6. | 8F | 80 cm | 0.035 in | 6 mm | 80 mm |
7. | 10F | 80 cm | 0.035 in | 12 mm | 100 mm |
8. | 9F | 80 cm | 0.035 in | 8 mm | 60 mm |
9. | 8F | 80 cm | 0.035 in | 6 mm | 100 mm |
10. | 10F | 80 cm | 0.035 in | 13.5 mm | 40 mm |
11. | --- | 117 cm | --- | 13.5 mm | 120 mm |
12. | 9F | 80 cm | 0.035 in | 8 mm | 40 mm |
13. | 8F | 80 cm | 0.035 in | 6 mm | 60 mm |
14. | 8F | 80 cm | 0.035 in | 6 mm | 60 mm |
15. | 9F | 80 cm | 0.035 in | 9 mm | 60 mm |
Fluency™ Plus Endovascular Stent Graft in Delhi | Fluency™ Plus Endovascular Stent Graft in Noida | Fluency™ Plus Endovascular Stent Graft in Gurugram | Fluency™ Plus Endovascular Stent Graft in NCR | Fluency™ Plus Endovascular Stent Graft in North India
Coviden Fixation Device Cybertieup
Scroll